    Types of cuts
    Lead equivalency mm
    Size
    Length mm
    Télécharger la fiche pdf
     
    BURLINGTON A10 EVAL Front Radiation Protection Apron

    High-Performance Lead Protection and Ergonomic Comfort for Medical Imaging Professionals

    The BURLINGTON A10 EVAL front radiation protection apron has been designed to provide effective protection against ionizing radiation while improving day-to-day wearing comfort. Thanks to its weight distribution system between the shoulders and hips, it helps reduce muscle fatigue and enhances ergonomics during X-ray examinations and procedures.

    Its adjustable design accommodates a wide range of body shapes through a crossed stretch back panel, hook-and-loop shoulder strap, and adjustable elastic belt. Lightweight and comfortable, the A10 EVAL apron is an ideal solution for healthcare professionals regularly exposed to radiation.

    EVAL Material: Certified Protection up to 150 kV

    Manufactured from BURLINGTON EVAL lead-based protective material, the A10 apron provides consistent and reliable protection across the full range of clinical imaging energies.

    - Available lead equivalencies: 0.35 mm Pb or 0.50 mm Pb
    - Tested and approved from 50 kV to 150 kV in accordance with IEC 61331-1:2014
    - Suitable for applications using X-ray energies above 125 kV
    - Lead equivalency determined using the inverse broad beam geometry method in accordance with IEC 61331-1:2014
    - 100% lead-based protective material for optimal radiation attenuation

    Recommended Applications

    The A10 EVAL front apron is particularly suitable for professionals working in:

    - General Radiography
    - Mammography
    - Dental Imaging
    - Computed Tomography
    - Nuclear Medicine

    Technical Features

    - Ergonomic front protection design
    - Adjustable elastic belt for improved weight distribution
    - Crossed stretch back panel for an optimal fit
    - Hook-and-loop shoulder strap
    - Front buckle closure
    - PVC-reinforced Velcro fastening for increased durability
    - Thick padded shoulders for enhanced comfort
    - Velcro replacement service available
    - Standard chest pocket

    Compliance and Certification

    - Compliant with IEC 61331-3:2014
    - H Category (Heavy Use)
    - CE Certified 89/686/EEC
    - Personal Protective Equipment (PPE) Category III
    - Tested and approved in accordance with NF EN 61331-3:2014

    BURLINGTON EVAL Material

    EVAL material combines a high level of radiation protection with excellent durability.

    - 4.9 kg/m2 at 0.35 mm Pb equivalency
    - 7.11 kg/m2 at 0.50 mm Pb equivalency
    - 98% recyclable material
    - Manufactured using a hot reformulation process

    30 Colours Available

    - Antibacterial outer coverings
    - 4 patterned PVC colours
    - 12 Polyurethane (PU) colours, plain or patterned
    - 14 Nylon colours, plain or patterned
    - Durable and easy-to-clean surfaces

    Key Benefits of the BURLINGTON A10 EVAL Apron

    - Certified lead protection up to 150 kV
    - Weight distribution between shoulders and hips
    - Enhanced comfort during extended wear
    - Adjustable fit for a wide range of body types
    - 100% lead-based material for consistent protection
    - Compliant with IEC 61331-1 and IEC 61331-3 standards
    - 98% recyclable material
    - 5 year warranty
    Material
    EVAL Plomb
    Packing
    80x41x11cm
    CE
    Classe III EPI
    UGAP
    4005427
    130028