Radiamètre portable de surveillance RDS31
RDS-31 is a small handheld, battery operated survey instrument using an energy compensated GM-tube as primary detector.
Due to its versatile functions and durability it is suited for a wide range of applications in civil defense, industrial and laboratory use.
Fields of application :
- Industry
- Nuclear
- Emergency units
- Army
Features :
- H*(10) ambient dose equivalent dose and dose rate
- wide range of external alpha, beta and gamma probes for direct connection with RDS-31
- new ergonomic design
- large graphic screen, confi gurable backlight with automatic illumination control
- high impact durable case construction , IP-67 immersion proof
- internal memory to store measurements
- flexible histogram functions
- firmware of instrument upgradable through cable link
- configurable shortcut functions
Radiological Characteristics :
- radiation detected: gamma and X-rays, 48keV...3MeV. Alpha, Beta radiation with an external probe
- detectors: one energy-compensated GM tube, energy response according to ambient dose equivalent H*(10)
- dose rate measurement range: 0.01 µSv/h...0.1 Sv/h or 1 µrem/h...10 rem/h
- dose measurement range: 0.01 µSv...10 Sv or 1 µrem...1000 rem
- resolution: three signifi cant digits or 0.01 µSv/h on dose rate and 0.01 µSv on dose ( 1 µrem/h on dose rate and 1 µrem on dose)
- calibration accuracy: ± 5%, 137Cs , calibration direction and in the calibration fi eld, temperature +20 °C (68°F)
- dose rate linearity: ± 15% ± least signifi cant number 0.05 µSv/h...0.1 Sv/h (5 µrem/h to 10rem/h)
- variation of the response due to photon radiation
Electrical Characteristics :
- power supply: 2 AA size batteries (alkaline or NiMH)
- contacts for external power and charging of NiMH battery (charging conditions +5... +35°C)
- operation time with fresh alcaline batteries more than 4 months at background radiation at +23°C, 8h use/24h
- operation time with fully charged NiMH batteries more than 1 month at background radiation at +23°C, 8h use/24h. At higher/lower temperatures the operation will be shorter.
Mechanical Characteristics :
- case high impact durable plastics reinforced with glass fi bre
- ergonomic design, rubber grip and cushion around the case
- enclosure class IP67 (IEC 60529), water proof including battery compartment
- dimensions: 100 x 67 x 33 mm (3.93 x 2.63 x 1.29 in)
- weight: 175 g without batteries (0.385 lb), 220 g with batteries (0.485 lb)
- wrist/neck strap
- belt clip
Due to its versatile functions and durability it is suited for a wide range of applications in civil defense, industrial and laboratory use.
Fields of application :
- Industry
- Nuclear
- Emergency units
- Army
Features :
- H*(10) ambient dose equivalent dose and dose rate
- wide range of external alpha, beta and gamma probes for direct connection with RDS-31
- new ergonomic design
- large graphic screen, confi gurable backlight with automatic illumination control
- high impact durable case construction , IP-67 immersion proof
- internal memory to store measurements
- flexible histogram functions
- firmware of instrument upgradable through cable link
- configurable shortcut functions
Radiological Characteristics :
- radiation detected: gamma and X-rays, 48keV...3MeV. Alpha, Beta radiation with an external probe
- detectors: one energy-compensated GM tube, energy response according to ambient dose equivalent H*(10)
- dose rate measurement range: 0.01 µSv/h...0.1 Sv/h or 1 µrem/h...10 rem/h
- dose measurement range: 0.01 µSv...10 Sv or 1 µrem...1000 rem
- resolution: three signifi cant digits or 0.01 µSv/h on dose rate and 0.01 µSv on dose ( 1 µrem/h on dose rate and 1 µrem on dose)
- calibration accuracy: ± 5%, 137Cs , calibration direction and in the calibration fi eld, temperature +20 °C (68°F)
- dose rate linearity: ± 15% ± least signifi cant number 0.05 µSv/h...0.1 Sv/h (5 µrem/h to 10rem/h)
- variation of the response due to photon radiation
Electrical Characteristics :
- power supply: 2 AA size batteries (alkaline or NiMH)
- contacts for external power and charging of NiMH battery (charging conditions +5... +35°C)
- operation time with fresh alcaline batteries more than 4 months at background radiation at +23°C, 8h use/24h
- operation time with fully charged NiMH batteries more than 1 month at background radiation at +23°C, 8h use/24h. At higher/lower temperatures the operation will be shorter.
Mechanical Characteristics :
- case high impact durable plastics reinforced with glass fi bre
- ergonomic design, rubber grip and cushion around the case
- enclosure class IP67 (IEC 60529), water proof including battery compartment
- dimensions: 100 x 67 x 33 mm (3.93 x 2.63 x 1.29 in)
- weight: 175 g without batteries (0.385 lb), 220 g with batteries (0.485 lb)
- wrist/neck strap
- belt clip
- Material
- ABS
- Colors
- Bleu marine
- UGAP reference
- 2094644
- Width mm
- 100
- Height mm
- 67
- Thickness mm
- 33
- Additional Information
- domaine industrie & sécurité
- Gross weight
- 0,35
- Net weight
- 0,22