Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV
    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV

    Personal radiation dosimeter DMC3000X detect X and GAMMA manual mode Energy range 15 KeV / 7 MeV

    Coating
    Colors
    Height mm
    Width mm
    Thickness mm
    Sterile
    Generate PDF
     
    DMC3000X operational dosimeter X and GAMMA for manual use

    Personal electronic dosimeter designed for the radiation protection of personnel in the medical and veterinary field with manual use mode.

    The manual model allows management of the dosimeter with the push button on the front and does not require the use of a terminal reader. However, the reading of the doses and the resetting of the dose is done manually.

    The manual model is recommended only for a single user.

    Our electronic dosimeter, the DMC3000X, covers a wide detection range of Gamma and X-rays.

    It is the result of more than 25 years of experience in the field of electronic dosimetry, with constant improvements based on feedback from our customers.
    KEY FEATURES
    - Loud alarm, 85 dB (A) typical, (> 90 dB (C) peak)
    - Vibrating alarm
    - Highly visible backlit display
    - Additional Beta, Neutron and telemetry modules
    - Factory upgradeable firmware
    - Simple 2-buttons navigation
    - Extended dose rate alarms
    - Dual ultrabright LED alarm
    - Superior X-ray and gamma energy response
    - Meets or exceeds applicable IEC and ANSI standards
    - Designed for ruggedness and durability

    PHYSICAL CHARACTERISTICS
    - Compliant with IEC 61526Ed. 3, ANSI 42.20(*)
    (*) isotropy Am-241 and Cs-137 with ? 75? angle

    MEASUREMENT AND DISPLAY
    - X and gamma energy range: 15 keV to 7 MeV
    - Energy response better than ? 20% (typically ? 10%) from 16 keV to 7 MeV
    - Accuracy Hp(10)
    = ? 5%* (Cs-137, ~ 24 mSv/h, 2.4 rem/h),
    = ? 10%*, (Am-241, ~ 23 mSv/h, 2.3 rem/h),
    = ? 10%** X-ray 16keV
    (*without ? 5% extended uncertainty k=2) ,
    (** without ? 9% extended uncertainty k=2)
    - Display units: mSv, ?Sv, or mrem
    - Display dose: 1 ?Sv to 10 Sv (0.1 mrem to 1000 rem)
    - Display rate: 10 ?Sv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 ?Sv/h to 10 Sv/h (0.1 mrem/h to 1000 rem/h) extended option.
    - Measurement range: 1 ?Sv to 10 Sv (0.1 mrem to 1000 rem) 0.1 ?Sv/h to 20 Sv/h (0.01 mrem/h to 2000 rem/h),
    - Saturation indication above 10 Sv (1000 rem) or 10 Sv/h (1000 rem/h)
    - Dose Rate Linearity: < ? 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 keV)

    ELECTRICAL CHARACTERISTICS
    - Standard AAA (LR03) 1.5 V Alkaline battery
    - 9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms)*
    - 2500 h battery life in continuous run, without excessive alarm*
    (*0.2% of the time in alarm)
    Material
    ABS
    Coating
    ABS
    Colors
    Bleu marine
    Width mm
    60
    Height mm
    87
    Thickness mm
    21
    Net weight kg
    0,12
    Packing
    16x13x7cm
    Gross weight kg
    0,2
    Sterile
    Non stérile
    CE
    Autres certifications