Pair of gloves radio attenuator UNIRAY size 8.5 disposable/Box 5 pair Unleaded-powder free-sterile R
Sterile single-use radio attenuating gloves size 8.5
Pair of sterile single-use radio-attenuating gloves intended for hand protection during surgery under ionizing radiation.
Thin and ergonomic, these gloves ensure perfect dexterity during X-ray procedures as well as excellent grip of the instruments used in functional explorations.
Each pair of gloves comes in a sterile pouch.
Composed of low-protein natural rubber, these gloves ensure very good hand hygiene and are guaranteed lead-free.
These gloves should only be used in scattered radiation. Under no circumstances should they be used in direct X-rays.
Technical performance:
? Nominal lead equivalence 60kV - 120kV: 0.039mm
? An optimal combination of high attenuation and tactile sensitivity
- 63.1% attenuation at 60kVp / HVL 2.5mm Al
- 54.4% attenuation at 80kVp / HVL 2.5mm Al
- 47.4% attenuation at 100kVp / HVL 2.5mm Al
- 42.0% attenuation at 120kVp / HVL 2.5mm Al
Technical characteristics :
? Size: 8.5
? Sterile R
? Lead-free and non-toxic
? Powder-free
? Contains natural rubber
? Ecological
Standards and references:
? CE according to standard EN 61331-1:2014
? CE PPE 2016/425
? CE 93/42/CEE
? Test standards: EN 420:2003, EN 374:2003, EN 388:2016, EN 421:2010, EN 455:2000, EN ISO 10993
Pair of sterile single-use radio-attenuating gloves intended for hand protection during surgery under ionizing radiation.
Thin and ergonomic, these gloves ensure perfect dexterity during X-ray procedures as well as excellent grip of the instruments used in functional explorations.
Each pair of gloves comes in a sterile pouch.
Composed of low-protein natural rubber, these gloves ensure very good hand hygiene and are guaranteed lead-free.
These gloves should only be used in scattered radiation. Under no circumstances should they be used in direct X-rays.
Technical performance:
? Nominal lead equivalence 60kV - 120kV: 0.039mm
? An optimal combination of high attenuation and tactile sensitivity
- 63.1% attenuation at 60kVp / HVL 2.5mm Al
- 54.4% attenuation at 80kVp / HVL 2.5mm Al
- 47.4% attenuation at 100kVp / HVL 2.5mm Al
- 42.0% attenuation at 120kVp / HVL 2.5mm Al
Technical characteristics :
? Size: 8.5
? Sterile R
? Lead-free and non-toxic
? Powder-free
? Contains natural rubber
? Ecological
Standards and references:
? CE according to standard EN 61331-1:2014
? CE PPE 2016/425
? CE 93/42/CEE
? Test standards: EN 420:2003, EN 374:2003, EN 388:2016, EN 421:2010, EN 455:2000, EN ISO 10993
- Lead equivalence mm
- 0,039
- Material
- Caoutchouc naturel
- Coating
- Caoutchouc naturel
- Colors
- Sable
- Size
- 8.5
- Cut type
- Mixte
- Length mm
- 290
- Width mm
- 107
- Net weight kg
- 0,67
- Packing
- 29x17x6cm
- Gross weight kg
- 0,83
- Interventional procedure
- Vasculaire
- Sterile
- Stérile R
- CE
- DM Classe 1 stérile
316504