Skirt K303 Man 61cm Size XS Strata+ Lead Free Pb 035/025
Skirt K303 Man 61cm Size XS Strata+ Lead Free Pb 035/025
BURLINGTON K303 STRATA LEADFREE skirt with total overlap which offers an exceptional lead weight/equivalence ratio intended for all practitioners during face and profile incidence operations.
The K303 skirt offers very high lumbar support wich can be reinforced thanks to its optional wide elastic waistband : the ultimate solution for reducing back pain.
Perfectly adjusted to the waist, the K303 skirt has a large side pull buckle for tightening.
The K303 model is a one-piece enveloping skirt that will adapt to all your BURLINGTON vest models.
The K303 skirt is particularly suitable for interventional workers in radiography, scanner, cardiology for short, medium and long duration interventions.
This apron model is suitable for workers in general radiography, mammography and dentistry.
CONTRAINDICATIONS :
Do not use leadfree or lightweight aprons in the following cases:
� - If the voltages of the x-ray generators used are greater than 120 kV and lower than 150 kV
� - If you work with x-ray generators with voltages above 150 kV
� - In nuclear medicine, whatever the radionuclide used
STRATA LEADFREE MATERIAL FOR A PERFECT PROTECTION OF YOUR STAFF:
- The K303 STRATA LEADFREE series has been tested and approved at 50kV / 70kV / 90kV / 110kV in accordance with international standard IEC61331-1:2014.
- The K303 STRATA LEADFREE series guarantees a lead equivalency regardless of the energy when lower than 120kV due to the new laminate technology STRATA.
- The K303 STRATA LEADFREE series offers lead equivalence determined as described in IEC61331-1:2014, by the inverse wide beam geometry method.
CATEGORIES:
In accordance with the new standard IEC 61331-3:2014, the K303 STRATA LEADFREE skirt is delivered in the category:
- Category HC (Intensive use closed) Lead Equivalent 0.35/0.25mm or 0.50/0.25mm
TECHNICAL DATA :
- Frontal closure with Velcro for quick installation and removal of the apron
- Elastic back for better load distribution between waist and shoulders
- Thick shoulder pads for greater comfort
- Standard frontal pocket on the skirt
MATERIAL:
- BURLINGTON STRATA LEADFREE
- Rubber base, Bismuth (Bi) Atomic number 83, Antimony (Sb) Atomic number 51.
- Weight of 2.81 kg / m� in lead equivalence 0.25mm (Ws)
- Weight of 3.95 kg / m� in lead equivalence 0.35mm (Ws)
- Weight of 5.54 kg / m� in lead equivalence 0.50mm (Ws)
- Also in a heat reformulation manufacturing concept, this material is recycled to 98%
- The recycled material then makes it possible to manufacture the raw material again before rolling.
30 COLORS:
- All our tissues are treated Anti bacterial
- 4 PVC surface colors with patterns - Easy to clean
- 12 Polyurethane (PU) surface colors, plain or with patterns - Easy to clean
- 14 Plain or patterned Nylon surface colors - High resistance
WARRANTY:
- 2 YEARS
CERTIFICATION:
- CE 89/686/CEE
- Personal protective equipment - Class 3
- Laboratory approved according to the new standard NF EN 61331-3:2014
BURLINGTON K303 STRATA LEADFREE skirt with total overlap which offers an exceptional lead weight/equivalence ratio intended for all practitioners during face and profile incidence operations.
The K303 skirt offers very high lumbar support wich can be reinforced thanks to its optional wide elastic waistband : the ultimate solution for reducing back pain.
Perfectly adjusted to the waist, the K303 skirt has a large side pull buckle for tightening.
The K303 model is a one-piece enveloping skirt that will adapt to all your BURLINGTON vest models.
The K303 skirt is particularly suitable for interventional workers in radiography, scanner, cardiology for short, medium and long duration interventions.
This apron model is suitable for workers in general radiography, mammography and dentistry.
CONTRAINDICATIONS :
Do not use leadfree or lightweight aprons in the following cases:
� - If the voltages of the x-ray generators used are greater than 120 kV and lower than 150 kV
� - If you work with x-ray generators with voltages above 150 kV
� - In nuclear medicine, whatever the radionuclide used
STRATA LEADFREE MATERIAL FOR A PERFECT PROTECTION OF YOUR STAFF:
- The K303 STRATA LEADFREE series has been tested and approved at 50kV / 70kV / 90kV / 110kV in accordance with international standard IEC61331-1:2014.
- The K303 STRATA LEADFREE series guarantees a lead equivalency regardless of the energy when lower than 120kV due to the new laminate technology STRATA.
- The K303 STRATA LEADFREE series offers lead equivalence determined as described in IEC61331-1:2014, by the inverse wide beam geometry method.
CATEGORIES:
In accordance with the new standard IEC 61331-3:2014, the K303 STRATA LEADFREE skirt is delivered in the category:
- Category HC (Intensive use closed) Lead Equivalent 0.35/0.25mm or 0.50/0.25mm
TECHNICAL DATA :
- Frontal closure with Velcro for quick installation and removal of the apron
- Elastic back for better load distribution between waist and shoulders
- Thick shoulder pads for greater comfort
- Standard frontal pocket on the skirt
MATERIAL:
- BURLINGTON STRATA LEADFREE
- Rubber base, Bismuth (Bi) Atomic number 83, Antimony (Sb) Atomic number 51.
- Weight of 2.81 kg / m� in lead equivalence 0.25mm (Ws)
- Weight of 3.95 kg / m� in lead equivalence 0.35mm (Ws)
- Weight of 5.54 kg / m� in lead equivalence 0.50mm (Ws)
- Also in a heat reformulation manufacturing concept, this material is recycled to 98%
- The recycled material then makes it possible to manufacture the raw material again before rolling.
30 COLORS:
- All our tissues are treated Anti bacterial
- 4 PVC surface colors with patterns - Easy to clean
- 12 Polyurethane (PU) surface colors, plain or with patterns - Easy to clean
- 14 Plain or patterned Nylon surface colors - High resistance
WARRANTY:
- 2 YEARS
CERTIFICATION:
- CE 89/686/CEE
- Personal protective equipment - Class 3
- Laboratory approved according to the new standard NF EN 61331-3:2014
- Lead equivalence mm
- 0,35/0,25
- Material
- STRATA Sans plomb
- Coating
- Nylon enduit antibactérien
- Size
- XS
- Cut type
- homme
- Net weight kg
- 2,47
- Packing
- 80x41x11cm
- Gross weight kg
- 2,8
- Sterile
- Non stérile
- CE
- Classe III EPI
130773