    Lead equivalency mm
    Coating
    Size
    Types of cuts
    Sterile
    Generate PDF
     
    Vest Strech PVEST Man 55 cm size XL Eval lead Pb 050/025

    BURLINGTON PVEST EVAL vest with total overlap which offers an exceptional lead weight/equivalence ratio intended for all practitioners during short and medium duration interventions in frontal and profile incidences.
    The PVEST vest offers adjustable lumbar support superior to other models and excellent weight distribution between the waist and shoulders.
    Closer to the body, the PVEST vest hugs the waist and anchors weight at the hips, eliminating weight loading on the shoulders, which significantly reduces the load on the back.
    The PVEST model is a one-piece wraparound jacket with front velcro closures. The jacket also has thick shoulder pads for better comfort.
    The PVEST vest is particularly suitable for interventional workers in radiography, scanner, cardiology for interventions. over 30 minutes.
    This vest model is suitable for workers in general radiology, mammography, dentistry as well as computed tomography and nuclear medicine.

    EVAL MATERIAL FOR A PERFECT PROTECTION OF YOUR STAFF:
    - The PVEST EVAL series has been tested and approved from 50kV to 150kV in accordance with international standard IEC61331-1:2014.
    - The PVEST EVAL series guarantees a linear lead equivalency regardless of the energy used because of its protective material base 100% lead
    - The PVEST EVAL series also benefits from the extension to 150kV allowing the use of the aprons during interventions involving an exposure to a radiation of energy greater than 125kV.
    - The PVEST EVAL series offers lead equivalence determined as described in IEC61331-1:2014, by the inverse wide beam geometry method.

    CATEGORIES:
    In accordance with the new standard IEC 61331-3:2014, the PVEST EVAL vest is delivered in the category:
    - Category HC (Intensive use closed) Lead Equivalent 0.35/0.25mm or 0.50/0.25mm

    TECHNICAL DATA :
    - Frontal closure with Velcro for quick installation and removal of the apron
    - Elastic back for better load distribution between waist and shoulders
    - Thick shoulder pads for greater comfort
    - Standard chest pocket

    MATERIAL:
    - BURLINGTON EVAL
    - Rubber base, Lead (Pb) Atomic number 82
    - Weight of 3.62 kg / m� in lead equivalence 0.25mm (Ws)
    - Weight of 4.9 kg / m� in lead equivalence 0.35mm (Ws)
    - Weight of 7.11 kg / m� in lead equivalence 0.50mm (Ws)
    - Also in a heat reformulation manufacturing concept, this material is recycled to 98%
    - The recycled material then makes it possible to manufacture the raw material again before rolling.

    30 COLORS:
    - All our tissues are treated Anti bacterial
    - 4 PVC surface colors with patterns - Easy to clean
    - 12 Polyurethane (PU) surface colors, plain or with patterns - Easy to clean
    - 14 Plain or patterned Nylon surface colors - High resistance

    WARRANTY:
    - 2 YEARS

    CERTIFICATION:
    - CE 89/686/CEE
    - Personal protective equipment - Class 3
    - Laboratory approved according to the new standard NF EN 61331-3:2014
    Lead equivalence mm
    0,50/0,25
    Material
    EVAL Plomb
    Coating
    Nylon enduit antibactérien
    Size
    XL
    Cut type
    homme
    Net weight kg
    4,36
    Packing
    80x41x11cm
    Gross weight kg
    4,69
    Sterile
    Non stérile
    CE
    Classe III EPI
    130314